Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Curr Biol ; 33(21): 4727-4732.e4, 2023 11 06.
Artigo em Inglês | MEDLINE | ID: mdl-37794583

RESUMO

Most mammals produce vocal sounds according to the myoelastic-aerodynamic (MEAD) principle, through self-sustaining oscillation of laryngeal tissues.1,2 In contrast, cats have long been believed to produce their low-frequency purr vocalizations through a radically different mechanism involving active muscle contractions (AMC), where neurally driven electromyographic burst patterns (typically at 20-30 Hz) cause the intrinsic laryngeal muscles to actively modulate the respiratory airflow. Direct empirical evidence for this AMC mechanism is sparse.3 Here, the fundamental frequency (fo) ranges of eight domestic cats (Felis silvestris catus) were investigated in an excised larynx setup, to test the prediction of the AMC hypothesis that vibration should be impossible without neuromuscular activity, and thus unattainable in excised larynx setups, which are based on MEAD principles. Surprisingly, all eight excised larynges produced self-sustained oscillations at typical cat purring rates. Histological analysis of cat larynges revealed the presence of connective tissue masses, up to 4 mm in diameter, embedded in the vocal fold.4 This vocal fold specialization appears to allow the unusually low fo values observed in purring. While our data do not fully reject the AMC hypothesis for purring, they show that cat larynges can easily produce sounds in the purr regime with fundamental frequencies of 25 to 30 Hz without neural input or muscular contraction. This strongly suggests that the physical and physiological basis of cat purring involves the same MEAD-based mechanisms as other cat vocalizations (e.g., meows) and most other vertebrate vocalizations but is potentially augmented by AMC.


Assuntos
Laringe , Animais , Gatos , Laringe/fisiologia , Prega Vocal/fisiologia , Vocalização Animal/fisiologia , Som , Vibração , Músculos Laríngeos , Mamíferos
2.
J Appl Physiol (1985) ; 124(1): 34-39, 2018 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-28839006

RESUMO

The fluid mechanics of whistling involve the instability of an air jet, resultant vortex rings, and the interaction of these rings with rigid boundaries (see http://www.canal-u.tv/video/cerimes/etude_radiocinematographique_d_un_siffleur_turc_de_kuskoy.13056 and Meyer J. Whistled Languages. Berlin, Germany: Springer, 2015, p. 74-774). Experimental models support the hypothesis that the sound in human whistling is generated by a Helmholtz resonator, suggesting that the oral cavity acts as a resonant chamber bounded by two orifices, posteriorly by raising the tongue to the hard palate, and anteriorly by pursed lips (Henrywood RH, Agarwal A. Phys Fluids 25: 107101, 2013). However, the detailed anatomical changes in the vocal tract and their relation to the frequencies generated have not been described in the literature. In this study, videofluoroscopic and simultaneous audio recordings were made of subjects whistling with the bilabial (i.e., "puckered lip") technique. One whistling subject was also recorded, using magnetic resonance imaging. As predicted by theory, the frequency of sound generated decreased as the size of the resonant cavity increased; this relationship was preserved throughout various whistling tasks and was consistent across subjects. Changes in the size of the resonant cavity were primarily modulated by tongue position rather than jaw opening and closing. Additionally, when high-frequency notes were produced, lateral chambers formed in the buccal space. These results provide the first dynamic anatomical evidence concerning the acoustic production of human whistling. NEW & NOTEWORTHY We establish a new and much firmer quantitative and physiological footing to current theoretical models on human whistling. We also document a novel lateral airflow mechanism used by both of our participants to produce high-frequency notes.


Assuntos
Boca/fisiologia , Faringe/fisiologia , Canto/fisiologia , Adulto , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Boca/diagnóstico por imagem , Faringe/diagnóstico por imagem , Radiografia
3.
J Vis Exp ; (129)2017 11 25.
Artigo em Inglês | MEDLINE | ID: mdl-29286438

RESUMO

The voice of humans and most non-human mammals is generated in the larynx through self-sustaining oscillation of the vocal folds. Direct visual documentation of vocal fold vibration is challenging, particularly in non-human mammals. As an alternative, excised larynx experiments provide the opportunity to investigate vocal fold vibration under controlled physiological and physical conditions. However, the use of a full larynx merely provides a top view of the vocal folds, excluding crucial portions of the oscillating structures from observation during their interaction with aerodynamic forces. This limitation can be overcome by utilizing a hemi-larynx setup where one half of the larynx is mid-sagittally removed, providing both a superior and a lateral view of the remaining vocal fold during self-sustained oscillation. Here, a step-by-step guide for the anatomical preparation of hemi-laryngeal structures and their mounting on the laboratory bench is given. Exemplary phonation of the hemi-larynx preparation is documented with high-speed video data captured by two synchronized cameras (superior and lateral views), showing three-dimensional vocal fold motion and corresponding time-varying contact area. The documentation of the hemi-larynx setup in this publication will facilitate application and reliable repeatability in experimental research, providing voice scientists with the potential to better understand the biomechanics of voice production.


Assuntos
Laringe/fisiologia , Prega Vocal/fisiologia , Humanos , Laringe/anatomia & histologia , Fonação , Vibração , Prega Vocal/anatomia & histologia
4.
Sensors (Basel) ; 13(8): 9790-820, 2013 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-23912427

RESUMO

The possibility of achieving experimentally controlled, non-vocal acoustic production in non-human primates is a key step to enable the testing of a number of hypotheses on primate behavior and cognition. However, no device or solution is currently available, with the use of sensors in non-human animals being almost exclusively devoted to applications in food industry and animal surveillance. Specifically, no device exists which simultaneously allows: (i) spontaneous production of sound or music by non-human animals via object manipulation, (ii) systematical recording of data sensed from these movements, (iii) the possibility to alter the acoustic feedback properties of the object using remote control. We present two prototypes we developed for application with chimpanzees (Pan troglodytes) which, while fulfilling the aforementioned requirements, allow to arbitrarily associate sounds to physical object movements. The prototypes differ in sensing technology, costs, intended use and construction requirements. One prototype uses four piezoelectric elements embedded between layers of Plexiglas and foam. Strain data is sent to a computer running Python through an Arduino board. A second prototype consists in a modified Wii Remote contained in a gum toy. Acceleration data is sent via Bluetooth to a computer running Max/MSP. We successfully pilot tested the first device with a group of chimpanzees. We foresee using these devices for a range of cognitive experiments.


Assuntos
Acelerometria/instrumentação , Actigrafia/instrumentação , Cognição/fisiologia , Monitorização Ambulatorial/instrumentação , Movimento/fisiologia , Música , Reconhecimento Automatizado de Padrão/métodos , Acelerometria/veterinária , Acústica/instrumentação , Actigrafia/veterinária , Animais , Módulo de Elasticidade , Desenho de Equipamento , Análise de Falha de Equipamento , Sistemas Microeletromecânicos/instrumentação , Pan troglodytes , Espectrografia do Som/instrumentação , Espectrografia do Som/veterinária , Transdutores
5.
Neuropsychologia ; 44(14): 2972-86, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16916525

RESUMO

The present study describes in detail, for the first time, a case of failure with multiplication procedures in a right hemisphere damaged patient (PN). A careful, step-by-step, error analysis made possible to show that an important portion of PN's errors could be better explained as spatial in nature and specifically related to the demands of a multi-digit multiplication. These errors can be distinguished from other types of errors, including those, expected after a right hemisphere lesion, determined by a generic inability to deal with spatial material, or from other deficits, like neglect, affecting cognitive capacities across the board. The best explanation for PN's problems is that he might have difficulties in relying on a visuo-spatial store containing a layout representation specific to multiplication. As a consequence, while knowing what, when and how to carry out the various steps, PN does not know where. What he may thus lack is a spatial schema of multiplication. Such schema is thought to help normal calculators in overcoming working memory demands of complex calculation by representing the information of where exactly each sub-step should be placed.


Assuntos
Afasia/fisiopatologia , Lateralidade Funcional/fisiologia , Matemática , Reconhecimento Psicológico/fisiologia , Adulto , Afasia/etiologia , Afasia/patologia , Lesões Encefálicas/complicações , Lesões Encefálicas/patologia , Estudos de Casos e Controles , Humanos , Masculino , Testes Neuropsicológicos/estatística & dados numéricos , Tomografia Computadorizada por Raios X/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...